Building structure – remove the load-bearing wall! The whole building is in danger!!! Both the owner and the contractor were


In case of earthquake or other conditions, buildings may collapse, resulting in huge property losses and even casualties.

Source: Civil forum, surging news, 1818 golden eye, Shanxi financial media, engineering events, etc.

The exercise of rights by owners shall not endanger the safety of buildings or damage the legitimate rights and interests of other owners.

After the local government’s intervention, it has carried out danger relief and reinforcement of the house.

After appraisal, the house is rated as grade D, and the current structure can not meet the requirements for safe use.

On October 11, the police in Xiaoshan District, Hangzhou learned that the owner and contractor of the household had been taken criminal coercive measures on suspicion of negligently endangering public security in a dangerous way.

Changing the main body and load-bearing structure of the building without the design scheme proposed by the original design unit or the design unit with corresponding qualification level; 2、 Changing rooms or balconies without waterproof requirements into toilets and kitchen rooms; 3、 Expand the size of the original doors and windows on the load-bearing wall, and remove the brick and concrete wall connecting the balcony; 4、 Damage the original energy-saving facilities of the house and reduce the energy-saving effect; 5、 Other behaviors that affect the safety of building structure and use.

Lifting Insert

The building main body as mentioned in these Measures refers to the structural structure of the building entity, including roof, floor, beam, column, support, wall, connecting joint and foundation, etc.

After completion, a third party will be invited to assess the risk level, and the owner will not be allowed to return to live until it reaches level B or above.” at present, the owner of illegal decoration on the first floor has been controlled by the police, and the local government has issued resettlement fees to 36 families, Let everyone stay in a hotel temporarily or go to relatives and friends.

Because the official account official has adjusted the push rules, if you want to continue to receive the contents of the official account, please set the public building number of the building as the star sign, and more points of the “look at” and “praise” in the end of the article.

01020304 netizen divine comment: good guy, this is a group photo of crime ∨ extended reading the load-bearing wall of the house is the public part of the house, which plays an important role in the use safety and service life of the house.

“If you want to continue to receive the official account, please note that the” WeChat “is a public key.

As for the resident, he was criminally detained according to law on suspicion of endangering public security by dangerous means.

The behavior of downstairs residents removing the bearing wall of the house without authorization not only violates the owner’s Convention and property service contract signed with the property management company, but also damages the public interests and property rights and interests of adjacent owners.

It is understood that the building is a brick concrete structure, built in 1988, with 6 floors and 36 households.

If it is really rebuilt, who will pay the cost? Destroy the structural system and reduce the seismic performance of buildings.

The town government has asked the owner of the building to temporarily live in a hotel or join relatives and friends, and each household shall pay 4000 yuan of resettlement fee in advance, which shall be paid by the owner of the first floor of the accident; The surrounding aisles have also been closed to prevent injury to passing vehicles and pedestrians.

The resettlement cost is a small sum of money.

Other owners demand that it must be rebuilt.

After that, the restored structure should be reviewed and identified by a qualified testing and Identification Organization to assess whether it can meet the original design requirements.

Many online people mix him with the project of Zhejiang, and confuse the external wall insulation project of Changsha Xinhualian, which belongs to replacing flowers with trees, which are all false news.

Article 272 of the Civil Code stipulates that the owner has the right to occupy, use, profit from and dispose of the exclusive part of his building.

36 community residents were affected, so they had to move and choose to stay in a hotel or go to relatives and friends.

The solution given by the government is reinforcement, which is opposed by all residents of the community.

Coincidentally, the same thing happened many times in different places.

The term “load-bearing structure” as mentioned in these Measures refers to the main structural components and their connection joints that directly transfer their own weight and various external forces to the foundation foundation, including load-bearing walls, vertical poles, columns, frame columns, buttresses, floors, beams, roof trusses, suspension cables, etc.

Article 114 of the criminal law of the people’s Republic of China stipulates that [crime of arson] [crime of water conviction] [crime of explosion] [crime of throwing dangerous substances] [crime of endangering public security by dangerous methods] arson, water conviction, explosion, throwing toxic, radioactive, infectious disease pathogens and other substances or endangering public security by other dangerous methods, which have not caused serious consequences, He shall be sentenced to fixed-term imprisonment of not less than three years but not more than 10 years.

After confirming the situation, the police contacted the relevant departments, and the maintenance personnel reinforced and repaired the removed load-bearing wall at the first time.

The remaining 17 households in the street were urgently relocated and ordered to build the wall back.

Star setting: enter the official account homepage, click the “top” corner, click “set star”, and the official account will appear yellow Pentagram (Android   Recently, the owner of the first floor of 31 commercial apartments in Guali Town, Hangzhou, brutally renovated and knocked off the load-bearing wall of the floor without permission, resulting in the cracking of the wall, the inclination of the building, and the whole building became a dangerous building.

∨ the next group of pictures is also the construction site of savagely demolishing the load-bearing wall.

Recommended reading building structure – clear! In the next five years, support such construction enterprises to “grow bigger and stronger” building structures – Shanghai has made it clear that the registered designer responsibility system  ——  Violation scoring management measures…

Article 5 of the general provisions in Chapter II of the measures for the administration of residential interior decoration, the following acts are prohibited in residential interior decoration activities: 1.

In August 2019, a resident of a unit in a building in Heilongjiang wanted to expand some space, so he found several roadside construction teams that were neither professional nor rigorous, and demolished all five load-bearing walls in the house during decoration! Upstairs neighbors think this behavior is too dangerous, and immediately contact the property for treatment.

Building structure – what is anti floating anchor? Building structure – 9 dead and 8 injured! The 5-storey demolition building collapsed and was buried when the bus passed! Attention to building structure! Ministry of housing and urban rural development: from July 1, if the first-class constructor fails to apply for renewal of registration, the registered specialty will become invalid! Warm tips 1) some pictures in this article come from the Internet, and the copyright belongs to the original author and original source.

Article 5 of the measures for the administration of residential interior decoration stipulates that the following acts are prohibited in residential interior decoration activities: (1) changing the main body and load-bearing structure of the building without the design scheme proposed by the original design unit or the design unit with corresponding qualification level; (2) Changing rooms or balconies without waterproof requirements into toilets and kitchen rooms; (3) Expand the size of the original doors and windows on the load-bearing wall, and remove the brick and concrete wall connecting the balcony; (4) Damage the original energy-saving facilities of the house and reduce the energy-saving effect; (5) Other behaviors that affect the safety of building structure and use.

If the circumstances and consequences are serious and endanger social and public security, criminal responsibility may also be borne.

According to Article 69 of the regulations on the quality management of construction projects, if a decoration project involving changes in the main body or bearing structure of the building violates the provisions of these regulations and constructs without a design scheme, it shall be ordered to make corrections and be fined not less than 500000 yuan but not more than 1 million yuan; If a building user changes the main body and load-bearing structure of the building without authorization in the process of decoration, he shall be ordered to make corrections and be fined not less than 50000 yuan but not more than 100000 yuan.

Relevant person in charge of the town government: “the house has been discharged through reinforcement and maintenance for 30 to 45 days.

In case of any accident, the owner and relevant parties shall bear corresponding legal liabilities.