Fire prevention guidelines for farmhouse (home stay) buildings (Trial)


The fire resistance limit of column shall reach 2.0h and that of beam shall reach 1.0h;   3.

The construction materials of staircase partition wall, external wall adjacent to outdoor stairs and stairs shall be non combustible materials..

Every 25m ² At least one 2kg fire extinguisher shall be equipped.

The total construction area of leisure and entertainment area and catering area with entertainment function shall not be greater than 500m ²;   3.

The fire extinguisher can be water-based fire extinguisher or ABC dry powder fire extinguisher.

Article 6 when transforming cultural relics buildings into farmhouse Entertainment (home stay), they shall comply with the relevant provisions of the cultural relics department.

Each guest room shall be equipped with flashlight, escape mask or fire self rescue respirator and other facilities according to the number of accommodation, and the evacuation diagram shall be posted in the obvious part;    7.

Article 11 the entrances and exits of closed staircases, open staircases and outdoor staircases or the exits leading directly to the outside can be used as safety exits; When the main structure is made of combustible materials, the wooden stairs shall be treated with flame retardant, and the width and slope of the stairs shall meet the requirements of personnel evacuation.

This guideline is not applicable to traditional buildings such as Tulou, pit yard, cave, yurt and yurt.

Article 4} fire prevention transformation measures shall follow the principles of adjusting measures to local conditions and applying them safely.

Article 5 the farmhouse Entertainment (home stay) within the scope of application of these Guidelines shall not be included in the scope of fire control supervision and management of construction projects and fire safety inspection before the opening of public gathering places.

Lifting Anchor

The fire resistance limit of column shall reach 2.0h and that of beam shall reach 1.5h;   2.

In areas without water supply network, natural water intake facilities or fire pools should be set up during the reconstruction of villages and towns, and high-level fire pools should be set up in mountainous areas.

Article 12} the farmhouse (home stay) with non combustible materials such as walls, columns, beams, floors and roof load-bearing components shall meet the following fire safety requirements: 1 When steel structure is adopted, fire protection shall be carried out.

Article 8} when constructing water supply network in villages and towns with farmhouse (home stay), fire hydrants shall be equipped.

Chapter II Requirements for fire protection infrastructure Article 7 in villages and towns with farmhouse (home stay), the fire protection infrastructure shall be constructed and managed in a unified manner with the rural infrastructure.

When the evacuation distance from the room door to the staircase entrance is less than 15m, and the sum of the number of people on each floor evacuated by stairs does not exceed 25, one emergency exit can be set except the first floor;   4.

The construction materials of staircase partition wall, external wall adjacent to outdoor stairs and stairs shall be non combustible materials.

Independent smoke fire detection alarm or automatic fire alarm system shall be set;   5.

When the evacuation distance from the room door to the stair entrance is less than 15m, and the sum of the number of people on each floor evacuated by stairs does not exceed 50, one emergency exit can be set except the first floor;   3.

The capacity of fire pool should not be less than 144m ³, When the columns, beams and floors of farmhouse (home stay) in villages and towns are combustible materials, the capacity of fire pool should not be less than 200m ³。 Article 9 # in the areas where brick wood structure and wooden structure farmhouses (homestays) are continuously distributed, measures such as setting up fire isolation belts, setting up fire separation, opening up fire passages, improving the fire resistance rating of buildings, transforming water supply networks and adding fire water sources shall be taken to improve fire safety conditions and reduce fire risks.

Farmhouse (home stay) shall meet the following fire safety requirements: 1 The number of floors of buildings for operation shall not exceed 3;   2.

The fire extinguisher is set in the public part of each floor and the outlet of the first floor;   6.

In areas with existing water supply network but not equipped with fire hydrants, outdoor fire hydrants shall be uniformly configured during village and town reconstruction.

Article 13} walls, columns, beams and floors are made of non combustible materials, and the load-bearing components of the roof are made of combustible materials.

Article 2 in these guidelines, farmhouse Entertainment (home stay) refers to places located in towns (excluding Chengguan towns), townships and villages, which are transformed by villagers’ self built houses and provide consumers with accommodation, catering, leisure and entertainment, small retail and other services.

There shall be no less than 2 emergency exits on each floor, and the horizontal distance between the nearest edges of two adjacent emergency exits shall be greater than 5m.

When steel structure is adopted, fire protection shall be carried out.

If the fire safety technical measures of the farmhouse (home stay) that has been put into use do not meet the requirements of this guide, it shall be transformed according to the requirements of this guide to improve the fire safety technical measures.

Chapter III technical measures for fire safety article 10: farmhouse (home stay) buildings shall meet the following basic fire safety conditions: 1 Metal sandwich plates shall not be used as building materials;   2.

Farmhouse (home stay) beyond the above scale or newly built shall meet the requirements of code for fire protection in rural areas gb50039, code for design of hotel buildings jgj62 and code for fire protection design of buildings gb50016.

There shall be no less than 2 emergency exits on each floor, and the horizontal distance between the nearest edges of two adjacent emergency exits shall be greater than 5m.

Emergency exits, staircases and evacuation walkways shall be provided with visual continuous light evacuation indication signs, and staircases and evacuation walkways shall be provided with emergency lights.

Non combustible solid walls shall be used to separate different farmhouses (homestays) located in the same building, and evacuation shall be carried out independently;   4.

Fire prevention guidelines for farmhouse (home stay) buildings (for Trial Implementation) Chapter 1 General Provisions Article 1 this fire prevention guidelines for farmhouse (home stay) buildings are formulated in order to prevent fire in farmhouse (home stay) buildings, standardize fire prevention and transformation measures, strengthen fire safety management level, reduce fire risk, protect personal and property safety, and promote the development of rural tourism.

Article 3 this guideline is applicable to farmhouse Entertainment (home stay) with no more than 14 standard rooms (or single rooms), up to 4 floors and a construction area of no more than 800 m2.