Window width: the window width generally starts from 0.6m.
When it reaches four streams of people, middle handrails shall be added.
The center distance of parallel washbasins shall not be less than 0.70M.
The door leaf width of double doors or multiple doors should be 0.6 ~ 1.0m.
Escalator: 1.
8.
In the design of architectural quick questions, various types of dimensions often make us miserable.
The clear distance from the long side of the bathtub to the opposite wall shall not be less than 0.65M.
3.
Door height: 2 ~ 2.4m for people; The equipment tube well is 1.5-2m.
The railing height of balcony building shall not be less than 1.0m in multi-storey buildings and 1.1m in high-rise buildings.
4.
6.
3.
The height of toilet interval shall be 1.50 ~ 1.80m.
Ladder shaft length: floor height / Tan α+ (2.0 ~ 2.9m) + (2.0 ~ 2.3m) is not a small number.
8 bath toilet there are many data about bath toilet.
General high-rise buildings try not to set up or close the balcony, which involves many safety setting problems such as strong wind, heavy rain and falling objects hurting people.
The clear width of the stair landing shall not be less than the width of the ladder section, and shall not be less than 1 l0m。 4.
The minimum width of toilet squatting partition (m) × The depth (m) is 0.9 when the door is opened outside × 1.2; 0.9 when opening the door inside × 1.4。 2.
The height of stair handrail (from the leading edge of the step) should not be less than 0.90M; The height of outdoor stair handrail shall not be less than 1.05M.
In addition, the width of passages, stairs and doors leading to the machine room shall not be less than 1.20m, and the slope of stairs shall not be greater than 45 ° for the passage of equipment and personnel.
Aisle height: we divide the total height of the aisle into the following four parts: ① structural height; ② The height of equipment pipeline is generally about 0.6m, which depends on the section and layout of air duct and the arrangement of condensate pipe and automatic sprinkler pipe; ③ The structural height of flat roof is generally 0.05m; ④ Clear height, which is the size that designers should carefully grasp, is one of the main factors determining the floor height.
Handrails shall be set on at least one side of the stairs.
The door width of public buildings is generally 1m for single doors and 1.2 ~ 1.8m for double doors.
Another problem is that when using the rotating staircase as the evacuation ladder, it must meet the requirement that the tread width should not be less than 0.22m when the step is 0.25m away from the handrail or simple wall of the inner ring.
When the clear width of the ladder section reaches three streams of people, handrails shall be set on both sides.
7.
2.
It should also be noted that the window width of the full Bay will cause glare on the horizontal wall, which is inappropriate for classrooms and exhibition rooms.
Dip angle: generally 30 ° and 35 °; 3.
When the width of the stairwell is greater than 0.20m, the clearance of the vertical bar of the handrail shall not be greater than 0.11M to prevent children from falling.
Special attention should be paid to that it is not allowed to set only one step, at least two steps.
Step width: currently 0.6m 0.8m and 1.0m, depending on the manufacturer, the width is slightly different.
The height of shower interval shall be 1.80m.
The main ones in the exam are: 1.
The fabrication of door leaves should be considered for any width.
Aisle 1.
The clear distance from one side compartment to the opposite wall shall not be less than 1.10M when using inner door, and not less than 1.30M when using outer door..
The specification stipulates that the clear width of the corridor from the residence to the bedroom and living room should not be less than 1.0m.
2.
6.
There are not only many, but also difficult to summarize.
The clear distance from the outer edge of one-sided washbasin to the opposite wall shall not be less than 1.25m.
Window height: in general residential buildings, the height of the window is 1.5m, plus the height of the windowsill is 0.9m, then the top of the window is 2.4m away from the floor, leaving a structural height of 0.4m.
2.
4.
Learn quickly! 1.
Stair 1.
7 elevators and escalators in short, the depth of the waiting hall of residential elevators shall not be less than the depth of the car of the largest one in the elevator, and that of medium passenger elevators in public buildings shall not be less than 1.5 times of the depth of the car of the largest one in the elevator.
Ladder shaft width: single ladder: ladder width + 0.6m + 2 × 0.4m; Double ladder: 2 (ladder width + 0.6m) + 2 × 0.4m, of which 0.4m is the distance from the ladder side to the well entrance.
5 parapet generally, the parapet of multi-storey buildings is 1.0 ~ 1.2m high, but that of high-rise buildings is at least 1.2m high, usually 1.5 ~ 1.8m higher than the chest shoulder or even the head.
The regulations for hospital bed elevators are similar to those for passenger elevators.
The bottom height of window sash opening to public walkway shall not be less than 2.0m.
9.
α Is the inclination of the run.
Door size 1.
We can accumulate more detailed requirements in this regard in the future design.
4.
When multiple elevators are in line, it shall not be less than the sum of the car depths of opposite elevators, nor more than 4.50M.
Aisle width: the net width of the narrowest aisle in the residence shall not be less than 0.8m, which is a “one-way line”, and generally only one person is allowed to pass through.
In public buildings, the height of windowsill varies from 1.0 to 1.8m.
When the height of window sill is lower than 0.8m, protective measures shall be taken.
2 size of building window 1.
Door width: 0.9 ~ 1m for household door, 0.8-0.9m for room door, about 0.8m for kitchen door and 0.7 ~ 0.8m for toilet door of general residence.
2.
The center distance of side-by-side urination shall not be less than 0.65M.
Here, the Almighty civil engineer has sorted out the commonly used dimensions of architectural quick questions for you.
The clear width of the outer walkway of high-rise residential buildings and the aisle of public buildings is generally greater than 1.20m to meet the width of two people in parallel.
The width of the door for pipeline and maintenance is generally 0.6m.
Generally, the distance between the walls on both sides is 1.5 ~ 2.4m.
It should be noted that when calibrating the height of parapet, the structural height of thermal insulation layer and discharge slope rise should be deducted.
3.
2.
When multiple elevators are in parallel, it shall not be less than 2.40M.
The clear distance between the outer edges of bilateral washbasins shall not be less than 1.80m.
In high-rise buildings, this thickness is often more than 0.3m.
5.